關閉
立即諮詢

Sidecar

Sidecar (Liquid to air)

  1. The maximum cooling capacity can reach 150 kW.
  2. No need for external chiller and no concerns about condensation.
  3. No need to configure cold water pipelines, easy to install and move.
  4. Can be configured in the existing air-conditioned machine room, no additional construction costs.
  5. Can be used with any brand of liquid-cooled servers to achieve high cooling capacity in a single cabinet.

Product description

  1. The air-liquid cooling RDHx cabinet is equipped with an independent cooling circulation loop, providing 100% sensible heat cooling for liquid-cooled servers. It utilizes the air within the data center to operate the liquid-cooled servers, without the need for additional chilled water sources.
  2. Key components such as water pumps and inverters are designed with redundancy (1+1), ensuring 24/7 operation. The system can immediately detect the status of key components and, in the event of an unexpected issue, automatically switch components to maintain operation, preventing any downtime due to component failure. This reduces the need for hardware equipment in the data center and lowers the overall failure rate.
  3. The system provides industry-standard communication methods, transmitting real-time operating parameters of the liquid cooling system to the data center management center, making data center operation management more convenient and improving management efficiency.
Model Number SC080 SC088
Cooling Capacity 80kW (Air inlet 35℃/ liquid outlet 44.5℃) 80kW (Air inlet 35℃/ liquid outlet 44.5℃)
Dimensions 2352mm(H)(47U/44OU) x 600mm(W) x 1068mm (D) (Standard)
2352mm(H)(47U/44OU) x 600mm(W) x 1250mm (D) (Flange)
2352mm(H)(47U/44OU) x 600mm(W) x 1336mm (D) (FD83)
2352mm(H)(47U/44OU) x 600mm(W) x 1068mm (D) (Standard)
2352mm(H)(47U/44OU) x 600mm(W) x 1250mm (D) (Flange)
2352mm(H)(47U/44OU) x 600mm(W) x 1336mm (D) (FD83)
Coolant PG25 PG25
Coolant Volume 25.0 L 27.0 L
Maximum Operating Pressure 690 kPa (100 psl) 690 kPa (100 psl)
Weight (Operational) 270 kg 270 kg
Max. flow rate 80.0 LPM 100.0 LPM
Fan Operating Voltage DC 48V DC 48V
Fan size( L x W x H ) 200x200x70mm 200x200x70mm
Fan Speed 8000 RPM 8000 RPM
Fan Count 16 16
Total Flow rate 10000 CFM 10000 CFM
RPU Model Number TLA80 (5U) TLA128 (4U)
RPU Pump Dual redundant pumps (1+1) Triple redundant pumps (2+1)
RPU Operating Voltage 380V 3P 480V 3P+N+G
Ambient Temperature 20~35 ℃ 20~35 ℃
Total Power Consumption 10.5kW 10.5kW
Noise Level @1m 110 dBA 110 dBA
Dew point control No No
Leak detection Optional Optional
Communication TCP/IP
Modbus
SNMP(optional)
BACnet(optional)
TCP/IP
Modbus
SNMP(optional)
BACnet(optional)
SC130
Cooling Capacity 130kW (Air inlet 35℃/ liquid outlet 45℃)
Coolant PG25
Coolant Volume 40.0 L
Maximum Operating Pressure 690 kPa (100 psl)
Max. flow rate 195.0 LPM
Fan Operating Voltage DC 48V
Fan size( L x W x H ) 200x200x70mm
Fan Speed 8000 RPM
Fan Count 24
Total Flow rate 15000 CFM
RPU Model Number TLA168 (4U)
RPU Pump Triple redundant pumps (2+1)
RPU Operating Voltage 480V 3P4W
Ambient Temperature 20~35 ℃
Power Consumption 16kW
Noise Level 115 dBA
Dew point control No
Leak detection Optional
Communication TCP/IP
Modbus
SNMP(optional)
BACnet(optional)

Taipei HQ

  • Tel:+886-3-3181588
  • Fax: +886-3-3181585
  • Customer Service:+886-3-3181588 #808
  • GUI number : 90573794
  • 2nd Floor, No. 31, Keji 2nd Road, Guishan District, Taoyuan City, 33341
  • MGCooling@mgcooling.com.tw

Overseas location

TRIOTEK Technology Inc.

Room 20, No. 20, Mould Manufacturing Zone, Kunshan International Mould City, Yushan Town, Kunshan City, Jiangsu Province(+86)-512-36601460

COOLING TECH Inc.

West 11th Floor, Building 2, Zone 1, Ganghuaxing Industrial Park, No. 2, Chongqing Road, Fuyong Town, Bao’an District, Shenzhen City, Guangdong Province (+86)-130-2333-7529

COOLING TECH Inc.

Room 506, Building C, Phoenix Building, No. 30 Qingfeng North Road, Yubei District, Chongqing (+86) 13996253519

© 2022-2024 MGCooling All Rights Reserved.